Male AB Human Serum

Male AB Human Serum
Expiration Date:June 2023
Country of Final Processing: United States
Shipping: Material shipped by Air Freight or Truck at ≤ -20⁰C
Lot#:A13012
Preservative:None
Storage:≤ -20⁰C
Filtration: 0.2 µm Sterile Filter

TEST UNIT RESULTS
Appearance N/A Straw yellow
Hemoglobin mg/dL 4.7
Endotoxin EU/mL < 0.60
Mycoplasma, Barile N/A Negative
Osmolality mOsm/kg 286
Sterility N/A Negative for Growth
pH N/A 7.68
BIOCHEMICAL ASSAY
AST (SGOT) IU/L 19
ALT (SGPT) IU/L 15
Total Bilirubin mg/dL 0.2
Blood Urea Nitrogen (BUN) mg/dL 12
Cholesterol mg/dL 131
Glucose mg/dL 92
Triglyceride mg/dL 114
Creatinine mg/dl 0.8
Total Protein g/dL 5.3
Albumin g/dL 3.4
Globulin g/dL 1.9
A/G Ratio (Calc) N/A 1.8
Albumin/Creatinine Ratio g/mg Cr 4.3
Carbon Dioxide mEq/L 23
Calcium mg/dL 7.8
Potassium mEq/L 3.7
Sodium mmol/L 165
Phosphorus mg/dL 3
Chloride mmol/L 88
SPECIES IDENTIFICATION
Cat N/A Not Detected
Cattle N/A Not Detected
Deer N/A Not Detected
Dog N/A Not Detected
Goat N/A Not Detected
Horse N/A Not Detected
Mouse N/A Not Detected
Pig N/A Not Detected
Rabbit N/A Not Detected
Rat N/A Not Detected
Sheep N/A Not Detected
VIRAL MARKERS
Anti-HIV I/II N/A Negative / Non-reactive
HBsAg N/A Negative / Non-reactive
Anti-HCV N/A Negative / Non-reactive
HCV RNA N/A Negative / Non-reactive
HIV-1 RNA N/A Negative / Non-reactive
HBV-DNA N/A Negative / Non-reactive
HTLV I/II N/A Negative / Non-reactive
West Nile Virus N/A Negative / Non-reactive
Syphilis N/A Negative / Non-reactive
The product is intended for in vitro or further manufacturing use.
All units have been collected in the USA in FDA licensed facilities and tested with FDA approved methods. Blood center license #1193.